Part Number Hot Search : 
120DC P4SMA75A 96647 A42MX09 NJU7009 TK31E60W LC503 1N5272
Product Description
Full Text Search
 

To Download G5LA14CFDC24 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 g 5 l a g5la pcb power relay a cubic, single-pole 10a power relay ? economical cube relay with universal terminal footprint ? conforms to vde0435 ? ul recognized/csa certified. ? high switching power: 10a @ 250vac ? withstands impulse of up to 4,500v ? coil power consumption: 360mw ? ul class f coil insulation type also available ? tracking resistance: cti>250 model number legend application examples ? home appliance ? oa equipments ? vending machines, etc. ordering information note. when ordering, add the rated coil voltage to the model number. ratings coil note 1. the rated current and coil resistance are measured at a coil temperature of 23c with tolerances of 10%. 2. please avoid ultrasonic cleaning this relay. rohs compliant g5la- @ @ @ - @ - @ 123 4 5 1. number of poles 1: 1-pole 2. contact form none: spdt (1c) a: spst-no (1a) 3. enclosure rating none: flux protection 4: fully sealed 4. classification none: standard e: high capacity (nc side) 5. ul insulation system none: standard cf: class f classification terminal shape contact form enclosure rating model rated coil voltage minimum packing unit standard pcb terminals spst-no (1a) flux protection g5la-1a(-cf) 5vdc 9vdc 12vdc 24vdc 48vdc 100 pcs/tray fully-sealed g5la-1a4(-cf) spdt (1c) flux protection g5la-1(-cf) fully-sealed g5la-14(-cf) high-capacity spdt (1c) flux protection g5la-1-e(-cf) fully-sealed g5la-14-e(-cf) rated voltage (vdc) rated current (ma) coil resistance ( ) must operate voltage (v) must release voltage (v) max. voltage (v) power consumption (mw) % of rated voltage 57269.4 75% max. 10% min. 130% (at 85c) 170% (at 23c) approx. 360 940225 12 30 400 24 15 1600 48 10 4800 approx. 480 rated coil voltage example: g5la-1 dc 12
2 g5la pcb power relay g 5 l a contacts note. p level: 60 = 0.1 x 10 -5 /operation characteristics note. values in the above table are the initial values. item standard model high-capacity (-e) model contact material ag-alloy (cd free) load resistive load (cos =1) rated load no 10a at 250vac 10a at 24vdc no/nc 5a/5a at 125vac 5a/5a at 24vdc 5a/5a at 250vac 5a/5a at 24vdc rate carry current 10a (no), 5a (nc) 10a max. switching voltage 250vac, 24vdc max. switching current 10a (no), 5a (nc) 10a max. switching power no ac2,500va, dc240w no/nc ac625va, dc120w ac1,250vac, dc120w failure rate (reference value) 100ma at 5vdc contact resistance 100 m max. operate time 10 ms max. release time 5 ms max. max. switching frequency mechanical: 18,000 operations/hr electrical: 1,800 operations/hr (under rated load) insulaion resistance 1,000 m min. (at 500 vdc) dielectric strength 2,000 vac, 1ma 50/60hz for 1 min between coil and contacts 750 vac 1ma 50/60hz for 1 min between contacts of same polarity vibration resistance destruction: 10 to 55hz, 1.5mm double amplitude malfunction: 10 to 55hz, 1.5mm double amplitude shock resistance destruction: 1,000m/s 2 (approx. 100g) malfunction: 100 m/s 2 (approx. 10g) endurance mechanical: 10,000,000 operations min. electrical: approx. 100,000 operations ambient operating temperature -40 to 85 (with no icing or condensation) ambient operating humidity 5% to 85% weight approx. 7.5g
3 g5la pcb power relay g 5 l a engineering data maximum switching capacity (no) durability (no) (average value) ambient temperature vs. maximum coil voltage note. the 120 vac resistive load service life curve also applies for 250 vac resistive load. note. the maximum coil voltage refers to the maximum value in a varying range of operating power voltage not a continuous voltage. durability (x10 3 operations)
4 g5la pcb power relay g 5 l a dimensions note. all units are in millimeters unless otherwise indicated. terminal arrangement/internal connections (bottom view) pcb mounting holes (bottom view) tolerance: 0.1 mm unless specified g5la-1(-cf) g5la-14(-cf) g5la-1-e(-cf) g5la-14-e(-cf) 1 2 3 4 5 2 0.1 1.4 12 0.1 +0.2 0 +0.2 0 1.8 19.8 max (19.6)* 1 15.8 max (15.6)* 1.2 15.8 max (15.6)* 12 12.2 0.4 3.3 2 0.4 0.4 0.28 @ 0.5 12.2 0.1 2- ? 1.1 3- ? 1.3 1 2 3 5 12.2 0.1 2 0.1 1.4 12 0.1 +0.2 0 +0.2 0 1.8 19.8 max (19.6)* 15.8 max (15.6)* 0.4 1.2 15.8 max (15.6)* 3.3 0.4 1 12 2 12.2 0.28 @ 0.5 2- ? 1.1 2- ? 1.3 terminal arrangement/internal connections (bottom view) pcb mounting holes (bottom view) tolerance: 0.1 mm unless specified g5la-1a(-cf) g5la-1a4(-cf)
5 g5la pcb power relay g 5 l a approved standards ul recognized (file no. e41643) csa certified (file no. lr31928) vde certified (approval no. 40017051) model contact form coil ratings contact ratings number of test operations g5la spdt-no (1a) spst-no (1a) 5 to 48 vdc 10 a, 277 vac, general use, 40c 100,000 10 a, 30 vdc, resistive, 40c 50,000 1/2 hp, 125-250vac, 40c 1,000 10 a, 277 vac, general use, 85c (-cf type only) 50,000 200 w tungsten, 125 vac, 40c 100,000 spdt-nc (1b) 10 a, 125 vac, resistive, 40c 6,000 10 a, 277 vac, general use, 40c (-e type only) 100,000 10a, 24 vdc, resistive, 40c (-e type only) model contact form coil ratings contact ratings number of test operations g5la spdt-no (1a) spst-no (1a) 5 to 48 vdc 10 a, 277 vac, general use, 40c 6,000 10 a, 24 vdc, resistive, 40c 1/2 hp, 125-250vac, 40c 1,000 10 a, 277 vac, general use, 85c (-cf type only) 6,000 spdt-nc (1b) 10 a, 125 vac, resistive, 40c model contact form coil ratings contact ratings number of test operations g5la spdt-no (1a) spst-no (1a) 5, 9, 12, 24, 48 vdc 10 a, 250 vac, resistive, 85c (flux protection) 50,000 10 a, 250 vac, resistive, 85c (fully sealed) 10,000 12 a, 250 vac, resistive, 85c spdt (1c) 5 a, 250 vac, resistive, 85c (flux protection) 50,000 5 a, 250 vac, resistive, 85c (fully sealed) 10,000 ? application examples provided in this document are for reference only. in actual applications, confirm equipment functions and safety before using the product. ? consult your omron representative before using the product under conditions which are not described in the manual or applying t he product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other sys tems or equipment that may have a serious influence on lives and property if used improperly. make sure that the ratings and performance characteristics of the product p rovide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. omron corporation electronic and mechanical components company contact: www.omron.com/ecb cat. no. j184-e1-02 0113(1012)(o) note: do not use this document to operate the unit.


▲Up To Search▲   

 